Measure: AdditivesQualityCheck
Description
Supervision of quality of delivered additives. Thus the use of additives produced with substandard quality or the use of subsequently (intentionally or unintentionally) polluted additives is prevented. The aim is to prevent the pollution of drinking water caused by the use of polluted additives.
Event source types
External attacker
Internal attacker
Human fault
Natural phenomena
External supplier
Interdependent CI
Event types
Destruction
Interruption
Manipulation
Pollution
Risk reduction mechanism
Frequency/Likelihood
Threat Types
Physical
Cyber-Physical
Action characteristics
Proactive
Measure types
Physical Barriers
Control System
Consequence Mitigation
Action and Crisis Management Plans and Training
event_ measures
Event-Measure: 98516
Event-Measure: 98625
Event-Measure: 98756
Event-Measure: 99056
Event-Measure: 99555
Event-Measure: 99808
Event-Measure: 100211
Event-Measure: 101681
Event-Measure: 101876
Event-Measure: 101987
Event-Measure: 102127
Event-Measure: 102149
Event-Measure: 103348
Event-Measure: 103924
Event Consequences
Quantity
Quality
Financial
Reputation
Asset types
Drinking Water Network
Drinking Water Tanks
Pressure Boosting Station
Water Abstraction Points
Water Treatment Plants
Events
Basic Event 160 - Failure to regulate the temperature, humidity and air quality in environments where information systems are located
Basic Event 78 - Internal person adds substance to WTP coagulant storage tank
Gate 187 - Contamination of WTP chemical solutions
Basic Event 280 - External person physically destroys WDN servers
Basic Event 45 - Internal person adds substance to WTP disinfectant storage tank
Basic Event 162 - Internal person adds substance to WTP stored additives
Basic Event 217 - Failure to regulate the temperature, humidity and air quality in environments where information systems are located
Basic Event 81 - Additive and/or disinfectant overdose from WTP staff error
Basic Event 44 - External person adds substance to WTP disinfectant storage tank
Basic Event 77 - External person adds substance to WTP coagulant storage tank
Basic Event 161 - External person adds substance to WTP stored additives
Gate 189 - Additives composition altered
Gate 146 - Free chlorine residual in WDN
Gate 118 - Disinfectant composition altered
Specific Assets
Additives
Server
Measure ID
M40
Name
AdditivesQualityCheck
Risk reduction mechanism
Frequency/Likelihood
Action characteristics
Proactive