Asset type: Drinking Water Tanks
Description
Drinking water tanks are all tanks in which drinking water is stored before distribution. Drinking water tanks may comprise tanks at ground level and elevated tanks as well as water towers. In addition, small inflow tanks for pumps or intermediate tanks in water treatment plants are to be considered as they might be vulnerable to pollutions too.
Events
Gate 148 - Unavailability at the storarge and distribution network
Gate 234 - Contamination of WDN tank
Gate 235 - False alarm on WDN tank contamination
Gate 236 - Outflow of WDN tank is interrupted
Gate 237 - Outflow valve of WDN tank closed
Gate 239 - Mislead PLC controlled WDN tank refill process
Basic Event 53 - Biological, chemical or radioactive substance injected to water tank
Basic Event 234 - Quality sensor installed in WDN tank
Basic Event 152 - Man-in-the-Middle attack manipulates quality sensor signals
Basic Event 151 - External person physicaly manipulates tank quality sensor readings
Basic Event 240 - Upadate of OS causes false positive alarms from Event Detection System
Basic Event 232 - External person physically interrupts WDN tank outflow
Basic Event 233 - External person damages WDN tank
Gate 120 - Contamination of drinking water
Basic Event 52 - Restricted area authorization procedure failure
Basic Event 53 - Biological, chemical or radioactive substance injected to water tank
Basic Event 150 - No sensor or insufficient type of quality sensor in the tank
Basic Event 151 - External person physicaly manipulates tank quality sensor readings
Basic Event 152 - Man-in-the-Middle attack manipulates quality sensor signals
Measures
MotionDetectors
CameraSurveillance
FencesAndWalls
Patrols
FloodProtection
SecureDoorsAndWindows
SupervisionOfExternals
SmokeDetectors
ContainmentStructures
OscillationSensors
ValvePositionSensors
LevelSensors
AutomatedValveControl
OperatingParameterSurveillance
ProcedureForPersonnelChanges
EmployeesTrainings
SecurityCheckOfEmployees
EmergencyPlans
RedundantAssetsAndInfrastructures
DistributedEnergySupply
EmergencyGenerators
AdditionalStorageCapacity
WaterIntakeAdaption
WaterQualityOnlineSurveillance
WaterTreatmentControl
WaterQualityOfflineSurveillance
MonitoringAndControlOfDistributionSystem
WaterNetworkInterventionsForWaterSupplyRecovery
AdditivesQualityCheck
InfrastructureAndAssetInspections
InformationSecurityGuidelines
InformationSecurityManagementSystem
PasswordSecurity
TwoFactorAuthentification
RestrictedAccesToITSytem
NonManipulationConnectionTool
CryptographicProcesses
DataBackups
AppropriateLayingOfWires
ServerRoomSetup
MirroredSCADA
MalwareProtectionGuidelines
MalwareProtectionSoftware
BinaryContacts
EntranceAccessControl
SecureLocks
DiscreetAppearance
FiltersInAerationProcesses
PressureAndFlowSensors
NetworkSeparation
DataIntegrityCheck
PatchAndChangeManagement
NetworkTrafficAnalysis
SecurityOfWirelessNetworks
SoftwareManagement
MobileDeviceUsageRules
DeletionAndDestructionOfDataCarriers
SecureOutsourcing
Documentation
IdentificationClassificationAndRiskAssessmentTool
Name