Home
FT
STOP-IT Quantity FT
STOP-IT Water Quality FT
Import
List
SP Wizard
Risknought
Lists
Measures
Events
Tools
ST Procedures
Search
Login
Measure: WaterQualityOfflineSurveillance
Description
Offline monitoring of water quality parameters in the distribution systems to comply with the water quality standards under all circumstances.
Event source types
External attacker
Internal attacker
Human fault
Natural phenomena
External supplier
Event types
Destruction
Interruption
Manipulation
Pollution
Risk reduction mechanism
Frequency/Likelihood & Consequences
Threat Types
Cyber
Physical
Cyber-Physical
Action characteristics
Proactive & Reactive
Measure types
Cyber Barriers
Control System
Consequence Mitigation
Action and Crisis Management Plans and Training
event_ measures
Event-Measure: 98133
Event-Measure: 98134
Event-Measure: 98166
Event-Measure: 98190
Event-Measure: 98199
Event-Measure: 98215
Event-Measure: 98257
Event-Measure: 98259
Event-Measure: 98328
Event-Measure: 98330
Event-Measure: 98361
Event-Measure: 98380
Event-Measure: 98456
Event-Measure: 98535
Event-Measure: 98617
Event-Measure: 98655
Event-Measure: 98670
Event-Measure: 98677
Event-Measure: 98733
Event-Measure: 98786
Event-Measure: 98865
Event-Measure: 98885
Event-Measure: 99001
Event-Measure: 99009
Event-Measure: 99060
Event-Measure: 99155
Event-Measure: 99191
Event-Measure: 99192
Event-Measure: 99271
Event-Measure: 99291
Event-Measure: 99336
Event-Measure: 99374
Event-Measure: 99381
Event-Measure: 99391
Event-Measure: 99509
Event-Measure: 99595
Event-Measure: 99622
Event-Measure: 99629
Event-Measure: 99703
Event-Measure: 99720
Event-Measure: 99748
Event-Measure: 99821
Event-Measure: 99823
Event-Measure: 99897
Event-Measure: 99954
Event-Measure: 99971
Event-Measure: 100025
Event-Measure: 100082
Event-Measure: 100228
Event-Measure: 100338
Event-Measure: 100371
Event-Measure: 100443
Event-Measure: 100451
Event-Measure: 100548
Event-Measure: 100557
Event-Measure: 100558
Event-Measure: 100671
Event-Measure: 100890
Event-Measure: 100898
Event-Measure: 100900
Event-Measure: 101021
Event-Measure: 101047
Event-Measure: 101130
Event-Measure: 101179
Event-Measure: 101213
Event-Measure: 101235
Event-Measure: 101266
Event-Measure: 101285
Event-Measure: 101319
Event-Measure: 101325
Event-Measure: 101393
Event-Measure: 101461
Event-Measure: 101539
Event-Measure: 101638
Event-Measure: 101645
Event-Measure: 101772
Event-Measure: 101820
Event-Measure: 101872
Event-Measure: 102091
Event-Measure: 102139
Event-Measure: 102205
Event-Measure: 102240
Event-Measure: 102252
Event-Measure: 102272
Event-Measure: 102352
Event-Measure: 102392
Event-Measure: 102394
Event-Measure: 102401
Event-Measure: 102431
Event-Measure: 102482
Event-Measure: 102483
Event-Measure: 102520
Event-Measure: 102545
Event-Measure: 102595
Event-Measure: 102647
Event-Measure: 102706
Event-Measure: 102776
Event-Measure: 102827
Event-Measure: 102836
Event-Measure: 102854
Event-Measure: 102877
Event-Measure: 102903
Event-Measure: 102918
Event-Measure: 102972
Event-Measure: 102973
Event-Measure: 103088
Event-Measure: 103118
Event-Measure: 103160
Event-Measure: 103232
Event-Measure: 103233
Event-Measure: 103345
Event-Measure: 103371
Event-Measure: 103448
Event-Measure: 103511
Event-Measure: 103519
Event-Measure: 103577
Event-Measure: 103587
Event-Measure: 103590
Event-Measure: 103635
Event-Measure: 103640
Event-Measure: 103709
Event-Measure: 103710
Event-Measure: 103738
Event-Measure: 103739
Event-Measure: 103784
Event-Measure: 103785
Event-Measure: 103864
Event-Measure: 103912
Event-Measure: 103913
Event-Measure: 104034
Event-Measure: 104050
Event Consequences
Quantity
Quality
Financial
Reputation
Asset types
Drinking Water Network
Drinking Water Tanks
Pressure Boosting Station
Water Abstraction Points
Water Treatment Plants
Events
Basic Event 151 - External person physicaly manipulates tank quality sensor readings
Basic Event 232 - External person physically interrupts WDN tank outflow
Basic Event 224 - External person destroys data transmission system of WTP power transformers
Basic Event 168 - External person physically manipulates surface water system sensor readings
Basic Event 251 - External person in situ manipulates PBS transmission devices
Basic Event 62 - Internal person silently takes over SCADA control
Basic Event 152 - Man-in-the-Middle attack manipulates quality sensor signals
Basic Event 179 - Man-in-the-Middle attack manipulates reservoir control signals
Basic Event 63 - Undetected SCADA hijacking software takes control of WTP operation
Basic Event 197 - External person physically manipulates well sensor signal
Gate 234 - Contamination of WDN tank
Basic Event 180 - Incorrect execution or failure of software acquired from an external party crashes reservoir control system
Basic Event 198 - External person breaks in to well control area and takes over SCADA
Basic Event 256 - External person jams PBS communications
Basic Event 282 - Failure to regulate the temperature, humidity and air quality in environments where information systems are located
Basic Event 257 - Incorrect execution or failure of software acquired from an external party crashes PBS control system
Basic Event 64 - Man-in-the-Middle attack manipulates WTP control signals
Gate 260 - WDN control system manipulated
Basic Event 227 - Fake news about contamination in WTP using manipulated water company public communication
Basic Event 199 - Internal person silently takes over abstraction well SCADA control
Basic Event 169 - Man-in-the-Middle attack manipulates surface water system sensor signal
Basic Event 266 - External person jams WDN valve communications
Basic Event 267 - Man-in-the-Middle attack manipulates WDN valve control signals
Basic Event 152 - Man-in-the-Middle attack manipulates quality sensor signals
Basic Event 209 - External person physically manipulates WTP sensor readings
Basic Event 49 - Internal person physically manipulates WTP sensor readings
Gate 185 - Undetected contamination of WTP chemical solutions
Basic Event 170 - External attacker manipulates surface water system transmission devices
Basic Event 50 - Man-in-the-Middle attack manipulates WTP sensor signal
Basic Event 52 - Restricted area authorization procedure failure
Basic Event 151 - External person physicaly manipulates tank quality sensor readings
Basic Event 148 - PRESSURE DIFFICIENCY CONDITIONS
Gate 236 - Outflow of WDN tank is interrupted
Basic Event 190 - External person physically destroys observation well sensors
Basic Event 252 - Man-in-the-Middle attack manipulates WDN PBS sensor signals
Basic Event 51 - Internal cyber manipulation of WTP sensor signal
Basic Event 53 - Biological, chemical or radioactive substance injected to water tank
Basic Event 253 - External person in situ destroys PBS sensors
Basic Event 82 - Organic matter present in consumers drinking water pipes
Basic Event 191 - External person physically destroys data transmission system of wells
Basic Event 200 - Incorrect execution or failure of software acquired from an external party crashes abstraction well control system
Gate 239 - Mislead PLC controlled WDN tank refill process
Basic Event 258 - Malware DoS to local PBS PLC
Basic Event 65 - DoS attack to dosing system PLC
Basic Event 259 - External person physically damages PBS PLC
Basic Event 254 - External person physically destroys PBS data transmission wires
Basic Event 210 - Man-in-the-Middle attack manipulates WTP sensor signal
Basic Event 201 - Malware performs DoS attack on abstraction well PLCs
Basic Event 66 - No back-up alternative for WTP dosing system PLC
Basic Event 218 - Accidental errors by authorized user while maintaining information system
Gate 186 - Quality verification process runs on altered WTP data
Basic Event 274 - Ransomeware denies access to the WDN control system
Basic Event 237 - Malware alters PLC statements that control WDN tank refill
Basic Event 275 - Malware alters WDN control statements
Basic Event 153 - External attacker manipulates WTP transmission devices
Basic Event 238 - External person in situ manipulates WDN tank transmission system
Basic Event 192 - External person physically destroys data transmission wires of wells
Basic Event 276 - SQL injection to data used for demand prediction
Basic Event 155 - External person physicaly manipulates abstraction point quality sensor readings
Basic Event 239 - Subcontractor physically disconnects local PLC
Basic Event 193 - External person jams data transmission of wells
Basic Event 163 - External person attacks surface water system management party e.g. water board
Basic Event 42 - External person physically destroys WTP sensors
Basic Event 171 - Human error in operating/using surface water management system
Gate 219 - Staff controlled hydraulic processes run without WTP data
Basic Event 213 - Internal person silently takes over WTP SCADA control
Basic Event 261 - Undetected SCADA hijacking software takes control of PBS operation
Basic Event 250 - Malware alters PLC statements that control pump
Basic Event 217 - Failure to regulate the temperature, humidity and air quality in environments where information systems are located
Basic Event 271 - WDN Control center destroyed by accidental flood
Gate 123 - Contamination at WDN water tank
Basic Event 43 - External person jams WTP sensor signal transmission
Gate 220 - Staff or PLC controlled hydraulic processes run on altered WTP data
Basic Event 219 - DoS attack to WTP process system PLC
Basic Event 272 - WDN control center destroyed by intentional flood
Basic Event 273 - External person attacks WDN control room
Gate 113 - Lower efficiency of WTP disinfectant undetected
Basic Event 277 - Malware tampers network topology characteristics on prediction models (e.g. tank volume curve)
Gate 193 - Surface water management system functions on altered data
Basic Event 159 - Incorrect execution or failure of software acquired from an external party crashes WTP control system
Basic Event 278 - Ransomware wipes out WDN control system files
Basic Event 233 - External person damages WDN tank
Basic Event 177 - External person breaks in to reservoir control area taking over SCADA
Basic Event 205 - External person physically destroys WTP sensors
Basic Event 164 - External person physically destroys surface water system sensors
Basic Event 206 - External person jams WTP sensor signal transmission
Basic Event 56 - Wrong connection of drinking water pipes with non-potable water pipes
Basic Event 214 - Undetected SCADA hijacking software takes control of WTP operation
Basic Event 46 - Internal person jams WTP sensor signal transmission
Basic Event 165 - External person jams surface water system sensor signal transmission
Basic Event 160 - Failure to regulate the temperature, humidity and air quality in environments where information systems are located
Basic Event 156 - Man-in-the-Middle attack manipulates abstraction point quality sensors
Basic Event 215 - Man-in-the-Middle attack manipulates WTP control signals
Basic Event 235 - External person in situ manipulates WDN tank level sensor
Basic Event 194 - External person manipulates transmission wires of wells
Basic Event 236 - Man-in-the-Middle attack manipulates WDN tank level sensor signals
Basic Event 47 - Internal person physically destroys WTP sensors
Basic Event 166 - External person jams surface water system sensor signal transmission
Basic Event 269 - External person physically destroys WDN pipes
Basic Event 157 - Man-in-the-Middle attack manipulates WDN quality sensor readings
Basic Event 216 - Incorrect execution or failure of software acquired from an external party crashes WTP control system
Basic Event 186 - Quality sensor transmission wires of observation wells manipulated
Basic Event 279 - Malware corrupts prediction model database
Basic Event 61 - External person breaks in to WTP and takes over SCADA undetected
Basic Event 195 - External person manipulates data transmission system of wells
Basic Event 196 - Man-in-the-Middle attack manipulates well sensor signal
Gate 176 - Staff controlled processes run without WTP data
Basic Event 270 - Control center destroyed by accidental fire
Gate 177 - Staff or PLC controlled processes run on altered WTP data
Basic Event 280 - External person physically destroys WDN servers
Basic Event 281 - Incorrect execution or failure of software acquired from an external party crashes WDN control system
Basic Event 149 - Biological, chemical or radioactive substance injected through pipe
Basic Event 154 - External attacker destroyes absraction point quality sensors
Basic Event 264 - Malware alters PLC statements that control valve
Basic Event 52 - Restricted area authorization procedure failure
Basic Event 187 - External person physically manipulates groundwater quality sensor readings
Gate 111 - Insufficient disinfection due to loss of WTP control
Basic Event 207 - External person destroys WTP transmission wires
Basic Event 265 - Man-in-the-Middle attack manipulates WDN valve sensor signals
Basic Event 53 - Biological, chemical or radioactive substance injected to water tank
Basic Event 208 - External attacker blocks WDN sensor signals to reach WTP
Basic Event 57 - Contamination source present around pipe
Basic Event 150 - No sensor or insufficient type of quality sensor in the tank
Basic Event 240 - Upadate of OS causes false positive alarms from Event Detection System
Basic Event 167 - External person physically manipulates surface water system sensor readings
Basic Event 158 - External attacker blocks WDN sensor reading to reach WTP
Basic Event 178 - Internal person silently takes over reservoir SCADA control
Basic Event 48 - External person physically manipulates WTP sensor readings
Basic Event 188 - Internal person physically manipulates groundwater quality sensor readings
Basic Event 189 - Man-in-the-Middle attack manipulates groundwater quality sensor signal
Basic Event 211 - External attacker manipulates WTP transmission devices
Specific Assets
Control Center
Control System
Drinking Water Pipes
Drinking Water Tanks
Media Channels
Sensor
Server
Transferred Information
Transmission Devices
Measure ID
M37
Name
WaterQualityOfflineSurveillance
Risk reduction mechanism
Frequency/Likelihood & Consequences
Action characteristics
Proactive & Reactive