Event: Gate 176 - Staff controlled processes run without WTP data
Description
Staff controlled processes run without WTP data
Fault Tree
STOP-IT Water Quality FT
Asset type
Water Treatment Plants
event_ measures
Event-Measure: 98210
Event-Measure: 98249
Event-Measure: 98465
Event-Measure: 98507
Event-Measure: 98727
Event-Measure: 98884
Event-Measure: 98924
Event-Measure: 99104
Event-Measure: 99308
Event-Measure: 99556
Event-Measure: 99597
Event-Measure: 99737
Event-Measure: 99773
Event-Measure: 99998
Event-Measure: 100039
Event-Measure: 100207
Event-Measure: 100243
Event-Measure: 100409
Event-Measure: 100454
Event-Measure: 100613
Event-Measure: 100825
Event-Measure: 101102
Event-Measure: 101147
Event-Measure: 101353
Event-Measure: 101531
Event-Measure: 101571
Event-Measure: 101957
Event-Measure: 102088
Event-Measure: 102167
Event-Measure: 102210
Event-Measure: 102375
Event-Measure: 102425
Event-Measure: 102472
Event-Measure: 102662
Event-Measure: 102690
Event-Measure: 102830
Event-Measure: 102916
Event-Measure: 103082
Event-Measure: 103118
Event-Measure: 103283
Event-Measure: 103633
Event-Measure: 103712
Event-Measure: 103755
Event-Measure: 103974
Gate
Gate 116
Nodes
Gate 176
Gate 176
Specific Asset
Control System
Threat Type
Physical
Measures
FencesAndWalls
CameraSurveillance
MotionDetectors
Patrols
FloodProtection
BarredWindows
SecureDoorsAndWindows
EntranceAccessControl
SecureLocks
DiscreetAppearance
SupervisionOfExternals
SmokeDetectors
FiltersInAerationProcesses
OscillationSensors
ValvePositionSensors
LevelSensors
AutomatedValveControl
OperatingParameterSurveillance
EmployeesTrainings
SecurityCheckOfEmployees
EmergencyPlans
RedundantAssetsAndInfrastructures
DistributedEnergySupply
EmergencyGenerators
AdditionalStorageCapacity
WaterIntakeAdaption
WaterQualityOnlineSurveillance
WaterTreatmentControl
WaterQualityOfflineSurveillance
MonitoringAndControlOfDistributionSystem
WaterNetworkInterventionsForWaterSupplyRecovery
InfrastructureAndAssetInspections
TwoFactorAuthentification
RestrictedAccesToITSytem
DataBackups
NetworkSeparation
AppropriateLayingOfWires
ServerRoomSetup
MirroredSCADA
DataIntegrityCheck
MalwareProtectionGuidelines
MalwareProtectionSoftware
Documentation
IdentificationClassificationAndRiskAssessmentTool
Event type
Manipulation
Event Consequence
Quality
Event source types
External attacker
Internal attacker
Human fault
Name
Gate 176
fault tree
STOP-IT Water Quality FT
asset type
Control System
event type
Manipulation