Home
FT
STOP-IT Quantity FT
STOP-IT Water Quality FT
Import
List
SP Wizard
Risknought
Lists
Measures
Events
Tools
ST Procedures
Search
Login
Measure: FloodProtection
Description
Implementation of flood protection measures. By the building of dams or object protection measures against floods the intrusion of flood water to sensitive sites shall be prevented. The aim is to prevent any assets or buildings from being damaged by flood water and to ensure an ongoing high water quality.
Event source types
External attacker
Internal attacker
Human fault
Natural phenomena
Event types
Destruction
Manipulation
Pollution
Risk reduction mechanism
Frequency/Likelihood
Threat Types
Cyber
Physical
Cyber-Physical
Action characteristics
Proactive
Measure types
Physical Barriers
Control System
Consequence Mitigation
Action and Crisis Management Plans and Training
event_ measures
Event-Measure: 98193
Event-Measure: 98195
Event-Measure: 98258
Event-Measure: 98260
Event-Measure: 98329
Event-Measure: 98338
Event-Measure: 98382
Event-Measure: 98455
Event-Measure: 98457
Event-Measure: 98524
Event-Measure: 98534
Event-Measure: 98569
Event-Measure: 98651
Event-Measure: 98676
Event-Measure: 98685
Event-Measure: 98792
Event-Measure: 98855
Event-Measure: 98884
Event-Measure: 99000
Event-Measure: 99187
Event-Measure: 99223
Event-Measure: 99224
Event-Measure: 99295
Event-Measure: 99335
Event-Measure: 99341
Event-Measure: 99413
Event-Measure: 99414
Event-Measure: 99416
Event-Measure: 99457
Event-Measure: 99484
Event-Measure: 99546
Event-Measure: 99600
Event-Measure: 99631
Event-Measure: 99673
Event-Measure: 99675
Event-Measure: 99788
Event-Measure: 99815
Event-Measure: 99820
Event-Measure: 99869
Event-Measure: 99900
Event-Measure: 99949
Event-Measure: 100123
Event-Measure: 100188
Event-Measure: 100202
Event-Measure: 100337
Event-Measure: 100369
Event-Measure: 100442
Event-Measure: 100450
Event-Measure: 100507
Event-Measure: 100547
Event-Measure: 100550
Event-Measure: 100622
Event-Measure: 100696
Event-Measure: 100738
Event-Measure: 100766
Event-Measure: 100777
Event-Measure: 100845
Event-Measure: 100897
Event-Measure: 100899
Event-Measure: 100907
Event-Measure: 100982
Event-Measure: 101045
Event-Measure: 101048
Event-Measure: 101101
Event-Measure: 101136
Event-Measure: 101181
Event-Measure: 101262
Event-Measure: 101263
Event-Measure: 101315
Event-Measure: 101361
Event-Measure: 101435
Event-Measure: 101471
Event-Measure: 101536
Event-Measure: 101579
Event-Measure: 101644
Event-Measure: 101680
Event-Measure: 101752
Event-Measure: 101871
Event-Measure: 101875
Event-Measure: 101990
Event-Measure: 102024
Event-Measure: 102058
Event-Measure: 102064
Event-Measure: 102093
Event-Measure: 102132
Event-Measure: 102140
Event-Measure: 102204
Event-Measure: 102211
Event-Measure: 102280
Event-Measure: 102321
Event-Measure: 102350
Event-Measure: 102353
Event-Measure: 102358
Event-Measure: 102395
Event-Measure: 102399
Event-Measure: 102433
Event-Measure: 102481
Event-Measure: 102484
Event-Measure: 102494
Event-Measure: 102566
Event-Measure: 102572
Event-Measure: 102573
Event-Measure: 102599
Event-Measure: 102615
Event-Measure: 102640
Event-Measure: 102646
Event-Measure: 102688
Event-Measure: 102707
Event-Measure: 102786
Event-Measure: 102829
Event-Measure: 102902
Event-Measure: 102937
Event-Measure: 102949
Event-Measure: 102979
Event-Measure: 103024
Event-Measure: 103253
Event-Measure: 103515
Event-Measure: 103589
Event-Measure: 103741
Event-Measure: 103852
Event-Measure: 103863
Event-Measure: 103865
Event-Measure: 103940
Event-Measure: 103981
Event-Measure: 103988
Event-Measure: 104009
Event-Measure: 104057
Event-Measure: 104065
Event Consequences
Quantity
Quality
Financial
Reputation
Asset types
Catchment Area
Drinking Water Tanks
Pressure Boosting Station
Raw Water Bodies
Water Abstraction Points
Water Treatment Plants
Events
Basic Event 65 - DoS attack to dosing system PLC
Basic Event 214 - Undetected SCADA hijacking software takes control of WTP operation
Basic Event 160 - Failure to regulate the temperature, humidity and air quality in environments where information systems are located
Basic Event 254 - External person physically destroys PBS data transmission wires
Basic Event 76 - External person physically damages WTP coagulation system
Basic Event 80 - External person induces chemical or radioactive substance to treated water tank
Basic Event 201 - Malware performs DoS attack on abstraction well PLCs
Basic Event 77 - External person adds substance to WTP coagulant storage tank
Basic Event 221 - Internal person physically destroys WTP process system
Basic Event 66 - No back-up alternative for WTP dosing system PLC
Basic Event 71 - Contaminated floodwater mixed with treated water in WTP
Gate 116 - Chemical overdosing due to misled WTP operation
Basic Event 216 - Incorrect execution or failure of software acquired from an external party crashes WTP control system
Basic Event 161 - External person adds substance to WTP stored additives
Basic Event 279 - Malware corrupts prediction model database
Basic Event 162 - Internal person adds substance to WTP stored additives
Basic Event 72 - External person induces biological substances to treated water tank
Gate 176 - Staff controlled processes run without WTP data
Gate 177 - Staff or PLC controlled processes run on altered WTP data
Basic Event 276 - SQL injection to data used for demand prediction
Basic Event 154 - External attacker destroyes absraction point quality sensors
Basic Event 255 - Man-in-the-Middle attack manipulates local power transformer signals
Basic Event 81 - Additive and/or disinfectant overdose from WTP staff error
Basic Event 163 - External person attacks surface water system management party e.g. water board
Basic Event 187 - External person physically manipulates groundwater quality sensor readings
Basic Event 42 - External person physically destroys WTP sensors
Basic Event 53 - Biological, chemical or radioactive substance injected to water tank
Basic Event 39 - External person adds substance through monitoring well
Basic Event 171 - Human error in operating/using surface water management system
Basic Event 67 - Natural phenomena destroy dosing system
Basic Event 250 - Malware alters PLC statements that control pump
Basic Event 217 - Failure to regulate the temperature, humidity and air quality in environments where information systems are located
Basic Event 78 - Internal person adds substance to WTP coagulant storage tank
Basic Event 48 - External person physically manipulates WTP sensor readings
Basic Event 188 - Internal person physically manipulates groundwater quality sensor readings
Basic Event 189 - Man-in-the-Middle attack manipulates groundwater quality sensor signal
Basic Event 68 - External person physically destroys WTP dosing system
Basic Event 73 - High biological load from improperly maintained WTP storage tank
Basic Event 224 - External person destroys data transmission system of WTP power transformers
Basic Event 39 - External person adds substance through monitoring well
Basic Event 219 - DoS attack to WTP process system PLC
Gate 113 - Lower efficiency of WTP disinfectant undetected
Gate 142 - Chemical overdosing due to loss of WTP control
Basic Event 225 - External person destroys WTP power transformer
Basic Event 257 - Incorrect execution or failure of software acquired from an external party crashes PBS control system
Gate 193 - Surface water management system functions on altered data
Gate 118 - Disinfectant composition altered
Gate 122 - THM by-product formation in WTP
Basic Event 233 - External person damages WDN tank
Gate 114 - Staff operate disinfection process without WTP data
Basic Event 205 - External person physically destroys WTP sensors
Basic Event 164 - External person physically destroys surface water system sensors
Basic Event 152 - Man-in-the-Middle attack manipulates quality sensor signals
Basic Event 209 - External person physically manipulates WTP sensor readings
Gate 143 - External contamination of WTP
Basic Event 156 - Man-in-the-Middle attack manipulates abstraction point quality sensors
Basic Event 49 - Internal person physically manipulates WTP sensor readings
Gate 185 - Undetected contamination of WTP chemical solutions
Basic Event 170 - External attacker manipulates surface water system transmission devices
Basic Event 194 - External person manipulates transmission wires of wells
Basic Event 50 - Man-in-the-Middle attack manipulates WTP sensor signal
Basic Event 47 - Internal person physically destroys WTP sensors
Basic Event 151 - External person physicaly manipulates tank quality sensor readings
Basic Event 190 - External person physically destroys observation well sensors
Basic Event 30 - Sewer line accidental break
Basic Event 186 - Quality sensor transmission wires of observation wells manipulated
Basic Event 61 - External person breaks in to WTP and takes over SCADA undetected
Basic Event 195 - External person manipulates data transmission system of wells
Basic Event 51 - Internal cyber manipulation of WTP sensor signal
Basic Event 196 - Man-in-the-Middle attack manipulates well sensor signal
Basic Event 191 - External person physically destroys data transmission system of wells
Basic Event 29 - Sewer line overflow from blockage
Gate 239 - Mislead PLC controlled WDN tank refill process
Basic Event 31 - Combined sewer line overflow from flooding
Basic Event 259 - External person physically damages PBS PLC
Gate 179 - Dosing system destroyed
Gate 117 - Staff or PLC controlled disinfection processes run on altered WTP data
Gate 111 - Insufficient disinfection due to loss of WTP control
Basic Event 207 - External person destroys WTP transmission wires
Basic Event 260 - Internal person silently takes over PBS SCADA control
Basic Event 240 - Upadate of OS causes false positive alarms from Event Detection System
Basic Event 218 - Accidental errors by authorized user while maintaining information system
Basic Event 167 - External person physically manipulates surface water system sensor readings
Gate 186 - Quality verification process runs on altered WTP data
Basic Event 27 - Serious spill from inderedependent Industry CI accident
Basic Event 178 - Internal person silently takes over reservoir SCADA control
Gate 119 - Insufficient disinfection process controlled by intruder
Gate 187 - Contamination of WTP chemical solutions
Basic Event 153 - External attacker manipulates WTP transmission devices
Basic Event 211 - External attacker manipulates WTP transmission devices
Basic Event 151 - External person physicaly manipulates tank quality sensor readings
Basic Event 232 - External person physically interrupts WDN tank outflow
Basic Event 41 - Disinfectant missdosage from WTP from operational staff error
Basic Event 168 - External person physically manipulates surface water system sensor readings
Basic Event 192 - External person physically destroys data transmission wires of wells
Basic Event 62 - Internal person silently takes over SCADA control
Basic Event 152 - Man-in-the-Middle attack manipulates quality sensor signals
Basic Event 179 - Man-in-the-Middle attack manipulates reservoir control signals
Basic Event 202 - External person destroys abstraction wells
Gate 189 - Additives composition altered
Basic Event 63 - Undetected SCADA hijacking software takes control of WTP operation
Basic Event 197 - External person physically manipulates well sensor signal
Gate 234 - Contamination of WDN tank
Basic Event 180 - Incorrect execution or failure of software acquired from an external party crashes reservoir control system
Basic Event 155 - External person physicaly manipulates abstraction point quality sensor readings
Basic Event 27 - Serious spill from inderedependent Industry CI accident
Basic Event 198 - External person breaks in to well control area and takes over SCADA
Basic Event 44 - External person adds substance to WTP disinfectant storage tank
Basic Event 32 - External person physically damages sewer line
Basic Event 45 - Internal person adds substance to WTP disinfectant storage tank
Basic Event 64 - Man-in-the-Middle attack manipulates WTP control signals
Gate 219 - Staff controlled hydraulic processes run without WTP data
Basic Event 213 - Internal person silently takes over WTP SCADA control
Basic Event 261 - Undetected SCADA hijacking software takes control of PBS operation
Basic Event 199 - Internal person silently takes over abstraction well SCADA control
Gate 220 - Staff or PLC controlled hydraulic processes run on altered WTP data
Basic Event 52 - Restricted area authorization procedure failure
Gate 182 - Seepage of contaminated floodwater through monitoring wells
Basic Event 252 - Man-in-the-Middle attack manipulates WDN PBS sensor signals
Basic Event 53 - Biological, chemical or radioactive substance injected to water tank
Basic Event 159 - Incorrect execution or failure of software acquired from an external party crashes WTP control system
Basic Event 253 - External person in situ destroys PBS sensors
Basic Event 69 - Internal person physically destroys WTP dosing system
Basic Event 177 - External person breaks in to reservoir control area taking over SCADA
Basic Event 200 - Incorrect execution or failure of software acquired from an external party crashes abstraction well control system
Basic Event 70 - Natural phenomena alter reagent dosing system
Basic Event 75 - Chlorination disinfection process in WTP
Basic Event 220 - External person physically destroys WTP process system
Specific Assets
Additives
Control Center
Control System
Dosing System
Drinking Water Tanks
Power Transformer
Pressure Boosting Station
Pump
Sensor
Server
Spring Water
Surface Water
Transmission Devices
Water under treatment
Well
Measure ID
M05
Name
FloodProtection
Risk reduction mechanism
Frequency/Likelihood
Action characteristics
Proactive