Event: Basic Event 240 - Upadate of OS causes false positive alarms from Event Detection System
Description
Upadate of OS causes false positive alarms from Event Detection System
Fault Tree
STOP-IT Quantity FT
Asset types
Drinking Water Network
Drinking Water Tanks
event_ measures
Event-Measure: 98400
Event-Measure: 98451
Event-Measure: 98493
Event-Measure: 98669
Event-Measure: 98710
Event-Measure: 98910
Event-Measure: 99124
Event-Measure: 99167
Event-Measure: 99332
Event-Measure: 99540
Event-Measure: 99762
Event-Measure: 100024
Event-Measure: 100233
Event-Measure: 100436
Event-Measure: 100481
Event-Measure: 100597
Event-Measure: 100634
Event-Measure: 100677
Event-Measure: 100856
Event-Measure: 100908
Event-Measure: 101084
Event-Measure: 101134
Event-Measure: 101306
Event-Measure: 101470
Event-Measure: 101556
Event-Measure: 101727
Event-Measure: 101764
Event-Measure: 101940
Event-Measure: 101983
Event-Measure: 102024
Event-Measure: 102151
Event-Measure: 102192
Event-Measure: 102235
Event-Measure: 102406
Event-Measure: 102459
Event-Measure: 102859
Event-Measure: 103022
Event-Measure: 103070
Event-Measure: 103101
Event-Measure: 103268
Event-Measure: 103313
Event-Measure: 103350
Event-Measure: 103479
Event-Measure: 103522
Event-Measure: 103697
Event-Measure: 103739
Event-Measure: 103961
Gate
Gate 235
Nodes
Basic Event 240
Basic Event 240
Specific Asset
Control System
Threat Types
Cyber
Cyber-Physical
Measures
FencesAndWalls
CameraSurveillance
MotionDetectors
Patrols
FloodProtection
SecureDoorsAndWindows
EntranceAccessControl
SupervisionOfExternals
SmokeDetectors
FiltersInAerationProcesses
PressureAndFlowSensors
ValvePositionSensors
LevelSensors
AutomatedValveControl
OperatingParameterSurveillance
ProcedureForPersonnelChanges
EmployeesTrainings
SecurityCheckOfEmployees
EmergencyPlans
RedundantAssetsAndInfrastructures
DistributedEnergySupply
EmergencyGenerators
AdditionalStorageCapacity
WaterIntakeAdaption
WaterQualityOnlineSurveillance
WaterTreatmentControl
WaterQualityOfflineSurveillance
MonitoringAndControlOfDistributionSystem
WaterNetworkInterventionsForWaterSupplyRecovery
InfrastructureAndAssetInspections
InformationSecurityGuidelines
InformationSecurityManagementSystem
PasswordSecurity
RestrictedAccesToITSytem
CryptographicProcesses
DataBackups
AppropriateLayingOfWires
ServerRoomSetup
MirroredSCADA
MalwareProtectionGuidelines
MalwareProtectionSoftware
SecurityOfWirelessNetworks
SoftwareManagement
DeletionAndDestructionOfDataCarriers
SecureOutsourcing
Documentation
IdentificationClassificationAndRiskAssessmentTool
Event type
Manipulation
Event Consequence
Quantity
Event source types
Human fault
External supplier
Name
Basic Event 240
fault tree
STOP-IT Quantity FT
asset type
Control System
event type
Manipulation